Split air conditioner outdoor condenser unit

Lennox (exact model not visible)

Generated blueprint render

Drag or tilt your phone to explore · tap a number to inspect a part

Parts

18 components · 16 internal

1

Primary heat exchanger

internal · sourced

Transfers heat from combustion to the supply air.

Duralok aluminized steel on ML180UHV furnace models.

lennox.com ↗
2

Hot surface igniter

internal · sourced

Electrically ignites the gas burners.

Hot surface ignition system, no standing pilot on ML180UHV.

lennox.com ↗
3

Redundant gas valve

internal · sourced

Controls and safely shuts off gas flow to the burners.

Redundant safety shutoff per CSA on ML180UHV.

lennox.com ↗
4

Burner assembly

internal · sourced

Mixes gas and air and produces the flame to heat the exchanger.

Identified as a core furnace module in SL297UHNV parts ID.

tech.lennoxintl.com ↗
5

Combustion air inducer

internal · sourced

Establishes proper combustion airflow and pre purge before ignition.

Assembly can be rotated 90 degrees to accommodate vent discharge.

lennox.com ↗
6

Combustion air pressure switch

internal · sourced

Proves inducer airflow or negative pressure before allowing ignition.

Single pole single throw proving switch tied to furnace control.

lennox.com ↗
7

Flame rollout switch

internal · sourced

Opens on flame rollout to shut down the burners for safety.

Called out in SL297UHNV parts identification.

tech.lennoxintl.com ↗
8

Furnace control and ECM blower controller

internal · sourced

Runs ignition sequence, monitors safeties, and modulates ECM blower for target airflow.

Varies PWM to adjust ECM motor speed and maintain constant CFM.

lennox.com ↗
9

Indoor blower motor and wheel

internal · sourced

Moves air across the heat exchanger or evaporator coil into the ducts.

1/2 to 1 hp motors with air volume up to about 2180 CFM depending on model.

lennox.com ↗
10

External static pressure limit logic

internal · sourced

Protects blower and adjusts airflow if duct static is too high.

Maintains target CFM until about 0.8 in. w.g. ESP then enters cut back mode.

lennox.com ↗
11

Gas manifold

internal · sourced

Distributes gas to the burners at the set pressure.

Typical manifold pressure 3.5 in. w.c. natural gas, 10.0 in. w.c. LP.

lennox.com ↗
12

Electrical service

internal · sourced

Provides power for controls, blower, inducer, and igniter.

120 V, 60 Hz, single phase supply on ML180UHV.

lennox.com ↗
13

Venting connection (80 percent furnace)

internal · sourced

Routes flue products to a chimney or metal vent.

4 inch round flue connection listed for ML180UHV models.

lennox.com ↗
14

Direct vent intake and exhaust (condensing furnace)

internal · sourced

Provides sealed combustion air intake and positive pressure exhaust to outdoors.

PVC intake and positively pressurized exhaust per SL297UHNV install.

tech.lennoxintl.com ↗
15

Air filter system

internal · sourced

Protects blower and coil and maintains indoor air quality.

Field provided high velocity filter required, recommended sizes listed in manual.

tech.lennoxintl.com ↗
16

Variable capacity DC inverter compressor (outdoor unit)

sourced

Modulates cooling capacity and efficiency in matched outdoor systems.

SL28XCV uses DC inverter with R 410A, SEER2 up to 25.80 depending on tonnage.

s7d9.scene7.com ↗
17

Outdoor condenser coil

sourced

Rejects heat from refrigerant to outdoor air.

Quantum aluminum coil construction on current Lennox AC models.

s7d9.scene7.com ↗
18

Communicating thermostat or control

internal · sourced

Coordinates staging or modulation and system diagnostics across matched components.

SL28XCV requires Lennox communicating thermostat, S40 or S30, and a variable speed communicating furnace or air handler.

s7d9.scene7.com ↗